Connecting air, catchments, and water exercises

Use the values given; do not look up other constants. Predict the direction of change before calculating.

1. Close the annual budget

Calculate residual acidity and reference-adjusted alkalinity export for the base case. Report annual equivalents and meq/L.

Work in annual equivalents before converting to a flow-weighted concentration.

Residual acidity = 10000 eq/year, or 0.0200 meq/L. Alkalinity export = 50000 − 10000 = 40000 eq/year, or 0.0800 meq/L. No pH follows without additional constraints.

2. Change water export

Double water export to 1.00 × 10⁹ L/year, holding acid and neutralisation amounts fixed only for this sensitivity exercise. Find residual acid-equivalent concentration. Is it reasonable to assume all real catchment processes stay unchanged?

Divide the same annual residual by the new annual volume.

Residual concentration is 0.0100 meq/L. In a real catchment, higher water flow could change weathering contact, retention, and transport. The fixed-flux sensitivity is an explicit mathematical assumption, not a universal hydrological response.

3. Interpret sediment indicators

Use the supplied oxygen, Fe, and phosphate-P comparison. State a balanced iron reduction half-reaction, explain possible P release, and name an alternative explanation.

The iron-bearing carrier changes; phosphate need not undergo redox.

FeOOH + 3 H⁺ + e⁻ → Fe²⁺ + 2 H₂O. Reduction/dissolution can release sorbed phosphate. Mixing with a separate Fe/P-rich porewater source, desorption changes, or other minerals could contribute. Measure Fe(II), porewater gradients, and phase inventories to distinguish them.

4. A reproducible chemical argument

Write a short report using activity C and the catchment/sediment evidence. Include one reaction, one hand-checked balance, one model figure, and an explanation of what is still uncertain.

Use the downloadable activity C report; distinguish invented observations from model outputs.

A sound response reports the base-case 0.0200 meq/L acid residual, distinguishes annual export from closed-water pH, explains a plausible Fe–P mechanism without claiming proof, and labels the contaminant plot as a separate first-order model. It states fixed boundaries and proposes a discriminating measurement rather than treating model curves as field measurements.

Assemble the short report

Use the activity C report template and its supporting files. Keep the compound model and catchment/sediment arguments in clearly identified sections. Include the completed prediction, hand calculation, model checks, figure interpretation, catchment equivalent budget, and a redox hypothesis with a discriminating observation. A classmate should be able to render the report from the saved files and understand which numbers are inputs, predictions, or constructed observations.

Explore: the annual catchment budget

Predict how less accessible neutralisation differs from more annual water export. Close the annual acid-equivalent balance before interpreting a concentration or trying to explain a pH observation.

Reference catchment: 40000 eq/year acid input minus 30000 eq/year neutralised leaves 10000 eq/year residual acid.

E1. Choose Worked catchment. Show that annual acid actually neutralised plus residual acid equals acid input. Calculate the reference-adjusted alkalinity.

E2. Compare Less neutralisation with Double water export. Identify which annual amounts change and which concentration changes are dilution alone.

E3. Choose Capacity exceeds input, then Exceed reference alkalinity. Explain why unused capacity is not automatically credited as extra alkalinity, and why a negative alkalinity balance is not a negative solute concentration.

Model conditions and hand check

Quantity Worked catchment Less neutralisation
Acid input 40000 eq/year 40000 eq/year
Acid actually neutralised 30000 eq/year 20000 eq/year
Residual acid 10000 eq/year 20000 eq/year
Adjusted alkalinity export 40000 eq/year 30000 eq/year
Adjusted alkalinity at 500 million L/year 0.0800 meq/L 0.0600 meq/L

The explicit reference alkalinity export is 50000 eq/year. In the worked case, residual acid is 0.0200 meq/L. Accessible neutralisation capacity caps how much added acid can react; unused capacity is not an additional source in this reference comparison. Other annual terms stay fixed when one slider changes. This is an annual flow-weighted budget, not a dynamic lake or a closed-water pulse. Predicting pH also requires carbon, gas exchange, and acid–base constraints.

More guided comparisons for week 5.