Fragmentation and size control

Building blocks · NGS library preparation

Johan Henriksson

What this deck is for

A human genome is three billion bases in 46 pieces. A sequencer reads a few hundred bases at a time, or, on a long-read machine, tens of kilobases. Between the two sits a cutting step, and then a sorting step.

  • Cut the DNA or RNA to a length the instrument and the question want
  • Sort the pieces so the library contains that length and little else
  • The cut leaves the ends in a particular state, which decides what you have to do next (end chemistry)

This deck covers the main ways of cutting, the targets set by the sequencer, and how to select by size, with one of the most-used and least-understood steps at the bench in detail: the bead ratio.

Why we cut

  • A short-read library is a population of inserts with the same adapters on both ends and a length you chose
  • Too long and clusters form poorly; too short and the reads run into the adapter
  • Fragment position is usually meant to be random, so every part of the genome is covered evenly

Seven ways to cut

  • Each leaves different ends and a different bias: that is what you select on
  • The first three are for making libraries from anything. The next three also report on the chromatin the DNA came from

Acoustic shearing

  • Focused ultrasound makes bubbles that collapse; the local shear force breaks the backbone. Nothing in it recognises sequence
  • Size is tuned by time and intensity. The output is near-random but ragged and damaged: end repair is needed (end chemistry)
  • The cost is an instrument and a tube per sample

Knierim et al. 2011, doi:10.1371/journal.pone.0028240

Enzymatic fragmentation

  • Kits (for example NEBNext Ultra II FS) fragment, repair and A-tail in one tube by time and temperature
  • No instrument, low input, easy to automate. A price: mild sequence bias, and artefacts if the reaction runs long

Poptsova et al. 2014, doi:10.1038/srep04532

Tagmentation

  • A hyperactive Tn5 transposase cuts the target and ligates an adapter to each new 5’ end in the same step, leaving a 9 nt gap that a polymerase fills in (transposases)
  • Fragmentation and adapter attachment become one reaction: the fastest prep, used in Nextera XT and ATAC-seq

Adey et al. 2010, doi:10.1186/gb-2010-11-12-r119; Picelli et al. 2014, doi:10.1101/gr.177881.114

Tagmentation: the size is set by a ratio

  • Tn5 cuts until it runs out of enzyme, not until it runs out of time. Fragment size therefore depends on the ratio of enzyme to DNA
  • Quantify input by fluorescence: contaminating RNA or free nucleotides make absorbance read high, and the library comes out too long

Restriction digests

  • Every fragment starts and ends at a recognition site: identical ends in every cell, but sizes set by the genome, not by you
  • That is a feature when you want the same loci every time (reduced-representation bisulfite sequencing, Hi-C, ddRAD), a flaw when you want even coverage

Meissner et al. 2005, doi:10.1093/nar/gki901

MNase and DNase I

  • MNase digests linker DNA between nucleosomes and leaves nucleosome-sized fragments. DNase I cuts DNA the chromatin has left open
  • The fragment is the measurement: where the cut falls reports what was bound. Protocols: DNase-seq, scMNase-seq

Boyle et al. 2008, doi:10.1016/j.cell.2007.12.014; Schones et al. 2008, doi:10.1016/j.cell.2008.02.022

Chemical and alkaline hydrolysis

  • RNA is fragmented in a buffer with divalent metal ions at 85-95 degrees, giving 2’,3’-cyclic phosphate and 5’-OH ends. These ends block direct ligation until repaired
  • Alkali denatures DNA but does not cut it. DNA breaks by depurination (heat, acid) or radicals, which is why bisulfite treatment fragments DNA by itself

Mortazavi et al. 2008, doi:10.1038/nmeth.1226

What the sequencer wants

  • Short-read clusters want inserts of a few hundred bases; long-read machines want what you started with
  • Cell-free DNA (shed into plasma by dying cells) and nucleosome-protected fragments arrive at their own natural length: size selection should not fight it
  • Ranges are typical working ones, not limits; check the current kit

Insert length against read length

  • Insert shorter than a read: the read goes through into the adapter and is wasted
  • Insert shorter than two reads: they overlap, which is fine and sometimes useful
  • Rule: choose the insert for the read length, then the method that delivers it

A cut gives a distribution, not a length

A sheared sample is a smear, typically two-fold either side of the mean. Three populations hurt you:

  • Too long: cluster poorly, or never leave the flow-cell surface
  • Too short: reads read adapter. Also, inserts shorter than the reads waste the cycles
  • Adapter dimers: about 120 bp of adapters with no insert, which amplify and cluster better than anything else

Size selection narrows the distribution and removes the worst. It does not make it a line: whichever method you use, the edge of the selection is a slope.

Head et al. 2014, doi:10.2144/000114133

Which window do you ask for?

  • The ratio is volume of bead suspension to volume of sample. A lower ratio means less PEG and binds only the long DNA. How the beads bind, and how to work out a bead volume, are in QC; here the question is which window to ask for
  • 1.8x binds nearly everything above ~100 bp, so it clears primers and nucleotides; ~0.8x begins to leave the short end behind
  • The curves are illustrative. Run your own ladder through your own beads

Hawkins et al. 1994, doi:10.1093/nar/22.21.4543; Rohland and Reich 2012, doi:10.1101/gr.128124.111

What a ratio actually does to a ladder

  • Each lane is the same ladder after one clean-up. Lower ratio, less PEG, higher cut-off: the short bands fade out from the bottom up
  • The edge is a slope, not a wall. At 0.8x a 300 bp fragment is half kept, so half of what you wanted is in the discarded supernatant
  • 1.8x keeps essentially everything above ~100 bp, which is why it is the default clean-up ratio and not a selection
  • Simulated from the curve above, not measured. The point is how to read such a panel, not these numbers

Two edges make a window

  • Step 1 at a low ratio binds the long fragments. Keep the supernatant
  • Step 2 raises the ratio. Now the target binds, and the short fragments stay in solution. Keep the beads
  • Together the two edges give a window; each edge is still a slope

A ratio is a PEG concentration

  • The final PEG concentration is a weighted average of sample and beads. Whatever PEG is already in the sample adds to the beads
  • The bead stock is assumed to be 20 % PEG here; vendors do not always publish it

What goes wrong with beads

  • PEG in the sample (ligase buffers, some master mixes): the same nominal ratio gives a lower cut-off
  • Wrong volume base in a double-sided clean-up: the second addition counted from the supernatant
  • Beads not at room temperature or not resuspended: the settled beads are the suspension’s weakest part, so the true ratio is off
  • Over-dried beads crack and release DNA poorly; old ethanol is not 80 % any more and washes away DNA
  • Small volumes: pipetting 3 ul of beads has an error that is a large part of the ratio

When a library looks wrong, ask about the beads before you blame the enzyme. The same ratios come back as a clean-up step, measured rather than designed, in QC.

Gel and PAGE

  • A gel puts a window on a ruler: you see the smear and cut the slice you want. PAGE does the same for small molecules to a few bases
  • It is slower and loses material; use it when two species are too close for beads to tell apart

Order changes the answer

  • Before or after the key chemistry? For RNA, fragmenting first gives even coverage, cutting the cDNA afterwards is biased to the 3’ end
  • Hi-C digests the chromatin before ligating and shears after, because ligation junctions are the data. Bisulfite fragments DNA by itself, so adapters go on after it, as in PBAT, or are made of methylated cytosines
  • Tagmentation of nuclei is the chemistry in ATAC-seq

Lieberman-Aiden et al. 2009, doi:10.1126/science.1181369; Miura et al. 2012, doi:10.1093/nar/gks454; Buenrostro et al. 2013, doi:10.1038/nmeth.2688

Partial digestion

  • A complete digest tells you what is between neighbouring sites. A partial digest gives overlapping fragments from which you can build a map
  • With MNase or DNase I the titration chooses what you measure: mono-nucleosomes with plenty of enzyme, a ladder with less. Always run a time course on a new sample
  • Under-digestion is a common silent fault in a Hi-C prep. Check a small aliquot before moving on

Bottleneck dilution: endpoints as labels

  • Random shear points are a free label. In a human cancer or T-cell clone, every cell with a provirus (a retroviral genome built into the host chromosome) in one place has the same junction but a different shear length. Count the lengths, count the cells
  • Dilution is the bottleneck: the number of molecules entering PCR should stay below the number of possible lengths, or the labels collide

Gillet et al. 2011, doi:10.1182/blood-2010-10-312926; Berry et al. 2012, doi:10.1093/bioinformatics/bts004

Fixed-length tags from Type IIS and IIG enzymes

  • Ordinary enzymes cut inside their site. A Type IIS or IIG enzyme binds in your linker and cuts into the neighbouring DNA
  • The tag is the same length for every molecule, so a few dozen bases identify a transcript or a cut position. CAGE makes 27 nt tags with EcoP15I

Velculescu et al. 1995, doi:10.1126/science.270.5235.484; Takahashi et al. 2012, doi:10.1038/nprot.2012.005

Not cutting at all

  • Long-read sequencing wants the molecule intact, so the protocol is mostly about not breaking it: wide-bore tips, no vortexing, few transfers, gentle lysis
  • Rapid and ultra-long kits use a transposase at a low ratio so that each molecule is cut once, not many times: rapid, ultra-long

Jain et al. 2018, doi:10.1038/nbt.4060

Which cut for which question

  • Whole-genome short reads: acoustic or enzymatic, then end repair and adapters. PCR-free needs more DNA and an instrument
  • Low input, fast: tagmentation; measure the input
  • Same loci in every cell: restriction digest
  • What was bound to the DNA: MNase or DNase I; tagmentation in nuclei
  • RNA: metal-ion hydrolysis before reverse transcription
  • Long reads: do not cut; or cut once
  • Always: pick the size window from the read length, choose beads or a gel by how close the contaminant is to your product, and calibrate on a ladder

Where this connects

Where this block is used

  • Genomic DNA — the fragmentation route follows from how much DNA you have
  • Chromatin — MNase, DNase I and Tn5, where the cut position is the measurement
  • Three-dimensional genome — the restriction enzyme you pick sets the contact resolution
  • Small RNA and low input — when the molecule is already short, the size window is most of the protocol
  • Long reads — the unit where the aim is not to cut, and what shears HMW DNA anyway

Enzymes and tricks

  • Nucleases — restriction enzymes, MNase and DNase I seen from the enzyme side
  • Tricks — methylation-sensitive digestion, and cutting used as a way to select