Design: a clinical whole genome from 1 µg of blood DNA
Question: germline variants and copy number across the whole genome, GC-extremes included. Sample: a blood draw, so micrograms of long, intact DNA.
With that much input, block 4 can be nothing, and the other four blocks have to hand the sequencer a finished molecule on their own
The whole walk is above; the next four slides take it one block at a time, asking after each what sits on the two ends. The protocol is TruSeq DNA PCR-Free
Acoustic shearing is unbiased by sequence, which is what even coverage needs (fragmentation)
350 bp is set against the read length and the cluster, not against the chemistry (what the sequencer wants)
Construct now: insert of about 350 bp, ragged ends, a mixture of overhangs and 5’-OH, which no ligase can use
Row 2 repairs and A-tails in the same tube; row 3 does blocks 1 to 3 at once, and returns later in this deck
Blocks 2 and 3: repair the ends, add one A, ligate the adapter
End repair leaves every end blunt with a 5’-phosphate, one 3’ A is added, and the adapter carries the matching T (end chemistry)
The A/T handshake is what keeps the product clean: inserts cannot join each other, and adapters cannot join each other
Construct now: adapter – insert – adapter, one at each end, the unpaired arms of each fork still single-stranded
Each of those enzyme steps ends in a bead clean-up, and every clean-up loses molecules
A-tailing and end repair as in Illumina’s TruSeq guide, see the collection page for TruSeq PCR-Free
Block 4: nothing, because the fork was already full length
A full-length adapter arrives with P5, i5 and R1 on one end and R2, i7 and P7 on the other, so the molecule is finished the moment it is ligated (the molecule)
Construct now, read out: P5-i5-R1-insert-R2-i7-P7. Every ligated fragment can seed a cluster, and no base of it has been copied
With stub adapters the flow-cell ends are missing and PCR installs them, so block 4 stops being optional
What that PCR costs — GC and length bias, duplicates, library complexity — is worked out in amplification
Kozarewa et al. 2009, doi:10.1038/nmeth.1311
Block 5: size select, count by qPCR, load
Bead size selection brings the trace to one peak at the design size; a sharp peak near 130 bp is adapter dimers, which would take cluster space
Fluorescence counts every molecule, including the ones that lost an adapter: qPCR counts only those carrying both flow-cell ends (cleanup and QC)
Construct at the flow cell: unchanged since block 3. The molecule that was ligated is the molecule that is read
The third trace belongs to the PCR route, where a second, larger peak means too many cycles
The same spine, blocks 1 to 3 in one enzyme: tagmentation
A Tn5 dimer loaded with adapters cuts the DNA and joins an adapter to each 5’ end (transposases)
Construct after that one step: adapter – insert – adapter, with a 9 nt gap on the other strand at each end
The adapters are stubs and the gap is unfilled, so the first PCR does both jobs: block 4 is not optional here
Less input and fewer steps, at the price of a sequence preference: Nextera XT and Illumina DNA Prep
Adey et al. 2010, doi:10.1186/gb-2010-11-12-r119
What the field does, side by side
Tagmentation kits give up PCR-free-ness for input and speed; ligation kits give up input for flatness
Illumina DNA Prep uses bead-linked transposomes, Tn5 held on beads so that a fixed number of enzyme sites does the cutting: yield saturates, and libraries pool without individual quantification above 100 ng
Nextera XT was designed around small genomes, and its 1 ng input is matched to them rather than to a human genome
Worked example: how many molecules do you really have?
10 ng of human DNA, 3.3 pg per haploid genome:
10 000 pg / 3.3 pg is about 3000 copies of every locus
Assume 20% of fragments end up with an adapter at both ends (an assumption: check your protocol): about 600 molecules per locus
30x sequencing: x = 30/600 = 0.05 reads per molecule, so about 97% unique on the saturation curve (amplification)
Now 100 pg: 30 copies, about 6 molecules per locus, x = 5 at 30x, and about 20% unique
At 100 pg, no extra sequencing rescues the library. Only more input or a different method does.
Degraded DNA is damaged before you start
Ancient and some forensic DNA, or DNA from FFPE blocks (formalin-fixed, paraffin-embedded tissue), is short, nicked, and full of deaminated cytosines (C becomes U, read as T)
The damage accumulates at molecule ends, so the read-end pattern is the signature that the DNA is authentic
Library prep must keep short molecules and decide what to do about the uracils
Briggs et al. 2007, doi:10.1073/pnas.0704665104
Deal with the uracils: UDG
Uracil-DNA glycosylase plus an endonuclease removes uracil, so calls become clean
Partial UDG removes it internally but leaves the ends, so authenticity can still be tested
Gansauge and Meyer 2013, doi:10.1038/nprot.2013.038
One cell: there is nothing to prepare a library from
A cell holds about 6.5 pg: two copies of each locus
Amplification must produce nanograms to micrograms, and it can fail in the three ways shown
Every single-cell WGA method is a different attempt to make that amplification even and faithful
Amplifying one genome is not amplifying a library
A bulk library is already millions of distinct molecules and PCR makes more of each. Whole-genome amplification has to create the library first, roughly a million-fold from two copies, and only then do blocks 1 to 3 run
So unevenness that a bulk library would absorb arrives here as a genotype: a locus copied from one allele and not the other reads as a homozygote, and an error made in the first copy sits in half the reads
MDA, MALBAC and PTA are three attempts at that amplification, and they differ in how many generations stand between the original molecule and each copy (amplification); the product then enters an ordinary ligation library
What you can call follows from the evenness you get: copy number tolerates noise in depth, single-nucleotide variants tolerate neither dropout nor an early error
After sequencing: read the run back
Duplicate rate and insert-size distribution say whether the library held as many distinct molecules as the run asked for
The GC-versus-coverage curve says whether the chemistry tracked the template or its own preferences
Fold-80 base penalty: how much more depth you would need for 80% of positions to reach the mean coverage. 1 is perfectly even, 2 means half the run went on evenness
These are the numbers that answer the question on the first slide; the Bioanalyzer trace only said the library was built
Design from the sample, then compare
The recurring exercise: given the question and the sample, derive the library, then compare with the kit
Where your design and the kit differ, ask what the vendor knew about the sample that you did not
Next: targeted sequencing uses the same blocks and adds a selection step
Summary
The sample decides the route: micrograms of intact DNA allow a PCR-free ligation library, in which the ligated molecule is the sequenced molecule
Low input is what forces PCR or tagmentation, and amplification holds what that costs
Damaged DNA needs end and uracil choices; a single-stranded library recovers the shortest molecules
A single cell has no library to prepare: whole-genome amplification has to make one, and its evenness decides what can be called
Read a library by its complexity, not only by its yield
Where this connects
Blocks this protocol uses
Fragmentation — shearing, enzymatic cutting or tagmentation, and the size window
End chemistry — why end repair and dA-tailing stand between the shear and the ligation
Handles — adapter ligation and transposition: two of the five ways to attach a known sequence
Amplification — the cycle budget, GC bias, duplicates; and MDA, MALBAC, PTA for one cell
Barcodes and UMIs — the index that lets libraries be pooled, the UMI that separates a duplicate from a coincidence