Every protocol in the collection, however different its first steps, ends at the same place: a molecule an Illumina flow cell can grab and a sequencer can read.
The previous deck said what the machine requires. This deck draws the molecule that meets those requirements, and teaches one skill: given any protocol, write down its final molecule, and from it the read structure.
Everything you will build in Part B is a way of making one of the parts in this deck
Everything that goes wrong at the sequencer is a part that is missing, wrong or in the wrong place
The molecule, part by part
Seven parts, always in this order. Four are fixed by the platform, two are chosen per sample, one is yours
Read it as a map: each read starts at a primer site and runs toward the next part
The simplest library there is: an amplicon
If you already know the sequence at both ends — a guide cassette in a screen, one exon, a tumour hotspot — there is nothing to fragment and nothing to ligate
Two primers sit on the known sequence. Their 5′ tails carry P5, an index and the Read 1 site on one side, and the Read 2 side on the other
The tails are not on the template, so cycle 1 copies the target, cycle 2 copies a tail, and from there the product is a finished library molecule
Hold on to this: the rest of the course exists because you usually do not know the ends
Two strands, four primers
A primer has the sequence of one strand, so it anneals to the other and reads the first strand’s sequence
That is why the Read 2 site on the drawn strand is written as its complement (R2 site′)
Real sequences: the TruSeq arms
Nothing mystical: 29 + 8 + 33 bases on one oligo, 33 + 8 + 24 on the other, plus the insert’s own A
The stem letters are the key to the next slides: they hold the two arms together
Illumina Adapter Sequences, as listed for TruSeq DNA PCR-free in the collection
The Y adapter
Two oligos pair only along a 12 bp stem; beyond it the arms are free and different
Ligated to both ends, so every strand is P5 arm … insert … P7 arm
Meyer & Kircher 2010, doi:10.1101/pdb.prot5448
Why fork it?
A straight adapter gives the same end twice: such a molecule cannot bridge and never clusters
Two straight adapters, mixed, waste half the library; the fork makes every end usable
Full adapters: everything arrives in the ligation
In TruSeq DNA PCR-free the purchased adapter already carries P5, P7, the index and both primer sites.
After end repair, A-tailing and ligation (end chemistry), the molecule is finished; no PCR is needed
That is the point of the kit: no PCR duplicates, no PCR bias in GC-rich DNA
The price: the library is quantified by qPCR, because only molecules with an adapter at both ends cluster, and a gel or Qubit cannot tell those from the rest (what qPCR and Qubit each measure)
The price again: all adapters are long oligos, each index a separate purchase
Tagmentation: one enzyme, two jobs
Tn5 loaded with adapter ends fragments and tags in a single reaction, at the same time
The tags join only the 5′ ends, leaving a 9-nt gap per end; in Nextera XT the 72 °C step before PCR fills it (transposases)
Adey et al. 2010, doi:10.1186/gb-2010-11-12-r119; Picelli et al. 2014, doi:10.1101/gr.177881.114; Tn5 9-bp stagger: Reznikoff 2008, doi:10.1146/annurev.genet.42.110807.091656
Tn5 does not choose which tag goes where
Tag A and tag B are loaded at random, so half the fragments are A/A or B/B
Those carry the same sequence at both ends, so each strand’s two ends are an inverted repeat. On denaturation they snap shut into a panhandle and the primer cannot get on
So they are not merely unamplifiable, they are suppressed — and that is what makes the system work: the PCR is spent on A/B, the only product that can end up with P5 at one end and P7 at the other (suppression PCR)
It still costs half the input molecules. This is the Nextera equivalent of the Y adapter
The Nextera molecule
Same parts as TruSeq, different junction: the primer sites contain the Tn5 mosaic end
Nextera XT and Illumina DNA Prep share this architecture; DNA Prep runs the tagmentation on beads, and uses 10-base unique dual indexes
Truncated adapters, completed by PCR
The ligation or tagmentation delivers only what is generic: the primer sites
Sample-specific parts, and the flow-cell ends, arrive as 5′ tails on PCR primers (attaching a handle)
In Nextera the tailed PCR is not optional: it is what turns half the fragments into clusterable molecules
A tailed primer, cycle by cycle
In cycle 1 only the 3′ part of the primer pairs; the tail is carried along
From cycle 2 the copies contain the tail, and from cycle 3 the whole primer pairs
Full or truncated: what you trade
Full adapters
Truncated adapters + tailed PCR
Where P5, P7, indexes arrive
in the ligation
in the index PCR
PCR needed
no, so PCR-free is possible
yes, a few cycles
Input
micrograms (1–2 µg for TruSeq PCR-free)
little (Nextera XT: 1 ng)
Adapter stock
long, indexed, expensive
short and generic
Index swapping to watch
free adapter left in the pool
free primer left in the pool
Both kinds hop indexes if free oligo survives into the pool: clean-up decides, not architecture. Costello et al. 2018, doi:10.1186/s12864-018-4703-0
Where the information lives
Every library carries two kinds of content: the insert, which is the biology, and the sample index, which says whose it is
Some protocols add further labels in the same places — a cell barcode, a UMI — and those belong to the protocols that need them (barcodes and UMIs, single cells)
What matters here is the geometry: a label is only readable if a primer site sits next to it
Placing a label
A label can sit in an index read, at the start of a read, or next to the insert
The earlier it is added, the earlier material can be pooled, and everything after that is one tube instead of many
When is strand information kept?
A DNA library has no strand information: ligated Y adapters go on either strand
RNA libraries keep it only if chemistry forces it: dUTP marking, or a primer that defines the end
Parkhomchuk et al. 2009, doi:10.1093/nar/gkp596; Levin et al. 2010, doi:10.1038/nmeth.1491
What does not cluster or read
A tube holds many kinds of molecule; the flow cell sorts them by whether they bridge
Adapter dimers are the worst: short, perfect, and they take clusters from the library
Size selection and bead clean-ups exist mostly to remove the bottom rows, and a trace shows you whether they worked (cleanup and QC)
Head et al. 2014, doi:10.2144/000114133
When the read outruns the insert
The adapter in your FASTQ is a measure of fragment size, not of a failed run
Both reads start AGATCGGAAGAGC; after that they differ, so one adapter list does not fit both
Construct to read structure
Step 1: list the parts in order. Step 2: draw each read as an arrow from its primer site
Step 3: count the bases the arrow covers. Anything between the site and the insert is read first
Step 4: add the sample-sheet entries: one cycle count per read, 0 for a read you skip
Read structure to construct
A core facility offers you 151 bases in Read 1, 151 in Read 2, and two 8-base index reads. Work backwards to the molecule:
Two index reads means two indexes, one at each end: i5 by P5, i7 by P7
Read 1 enters the insert from one side, Read 2 from the other, so there is a primer site on each side of the insert
151 + 151 of insert means an insert of at least about 300 bp, or the reads meet and run into the opposite adapter
The molecule is therefore P5 – i5 – Read 1 site – insert – Read 2 site – i7 – P7
State the cycle numbers as 151 / 8 / 8 / 151
If a design cannot be drawn this way, it cannot be sequenced as written; that is cheaper to learn on paper.
Using the NGS 101 tools
Two tools on NGS 101 turn this deck into practice:
Annotate sequence: paste a final molecule or an oligo. It marks every known adapter, primer or site, on either strand, and lists protocols that share them. Press Set example sequence and read the match table
Sample-sheet indexes: paste the two primers; it locates i5 and i7 and writes the sample-sheet columns for the instrument you pick, including the i5 orientation that differs between instruments
The Annotate tool matches exactly: it identifies parts, it does not prove a protocol
A protocol-reading routine
Find the final library in the protocol page; list its parts left to right
Say which parts arrive in which step: ligation, tagmentation, PCR, RT
Mark P5 and P7 ends and say whether they are the same
Mark every read arrow, then the read structure: R1 / I1 / I2 / R2
Ask which molecules in the tube cannot cluster, and which clusters but is useless
Ask where strand and orientation are decided
Try it on the four collection examples: TruSeq PCR-free, Nextera XT, Illumina DNA Prep, 10x 3′ v3.
Where this connects
Before this
Nucleic acids — the ends every junction in this molecule is made of