A human genome is about 3.1 billion base pairs, and in total RNA the great majority of molecules are ribosomal. A plasma sample carries a few molecules of tumour DNA among thousands of normal ones.
Sequencing everything and filtering afterwards wastes reads. Selection puts the effort in the chemistry instead: the wanted molecule is kept, or the unwanted one removed, before the sequencer sees either.
This deck covers the ways to do it, what each costs, and how each one fails.
Four families, one question
The question is always the same: what property differs between what I want and what I do not?
Sequence, an end, a size, a modification, a compartment: each suggests a different tool
Selection is a ratio, not a switch
Enrichment raises the on-target fraction; it never reaches 100%
Every step also loses material, so more rounds trade purity for yield and duplicates
Affinity: streptavidin and biotin
Biotin is a small tag that can be put on an oligo, a nucleotide or an antibody; streptavidin on a magnetic bead binds it almost irreversibly
That strength lets you wash hard, but you cannot release the bait intact: release the target by heat or alkali, or amplify on the bead
Oligo-dT selects a 3’ poly(A) tail, which keeps mature mRNA and discards rRNA, but is blind to degraded or non-polyadenylated RNA
Hybridisation capture with baits
Long biotinylated baits (about 100 to 120 nt) tile the region of interest and pull in any library fragment that overlaps them
A bait can tolerate some mismatches, so related sequences are captured too
Gnirke et al. 2009, doi:10.1038/nbt.1523
Why a captured library needs blockers
Adapters are identical on every fragment, so on-target fragments hybridise to off-target ones through them: off-target daisy-chaining
Blocking oligos cover the adapters; Cot-1 DNA covers human repeats, which are present in many fragments and would otherwise pull each other down
Capture worked example: tumour DNA in plasma
Circulating tumour DNA is a few percent of cell-free DNA, or far less. A panel of roughly a hundred kilobases captures the recurrently mutated regions and spends the reads there.
CAPP-Seq designed its panel by choosing regions that are mutated in most patients with a given cancer, so one panel serves many patients. See the protocol on NGS 101.
The trade: capture is sequence-specific, but not cheap. It costs a long hybridisation, two bead steps and a PCR, and it loses molecules on the way.
Newman et al. 2014, doi:10.1038/nm.3519
Depletion: RNase H and DNA oligos
Instead of keeping the wanted RNA, mark the unwanted one: oligos tiled along rRNA turn it into an RNA:DNA hybrid
RNase H cuts only the RNA in a hybrid, so mRNA is left alone, and this works on degraded or fixed samples where oligo-dT does not
Morlan et al. 2012, doi:10.1371/journal.pone.0042882
Depletion by Cas9 cutting
Cas9 with a pool of guides cuts the abundant fragments after adapter ligation
Each cut piece keeps only one adapter, so the PCR step cannot amplify it
Specificity comes from the guide, and the cut is made in vitro on library molecules
A 3’-modified oligo cannot be extended, so a polymerase that meets it stops
The blocker is tuned so that one mismatch lets it fall off: a rare variant amplifies while the wild-type is held back
Blockers also protect adapters and repeats in capture
Duplex-specific nuclease
Denature the cDNA, re-anneal for a set time, then digest what became double-stranded
It normalises abundance: common transcripts are removed, rare ones remain
Zhulidov et al. 2004, doi:10.1093/nar/gnh031
Choosing between capture and depletion
Positive selection
Depletion
You must know
the sequence to keep
the sequence to remove
Good when
the target is small and defined
the unwanted is abundant and few species
Bias
misses variants the bait does not match
leaves what the oligos do not cover
Typical case
exome, gene panel
rRNA, mitochondrial DNA, globin
A worked rule: if what you want is a few hundred genes, capture them. If what you want is the whole transcriptome except two or three abundant species, deplete those.
Depletion keeps the unknown; capture finds only the known.
Enzymatic selection: exonucleases
A closed circle has no end, so an exonuclease cannot start on it
Everything else linear is removed: unligated probe, unreacted adapter, carry-over genomic DNA
The same selectivity applies to your good molecules the moment they have a free end.
Pick by polarity and by strand. Some enzymes digest only single-stranded DNA, some only double-stranded; the wrong choice leaves the unwanted species or eats the wanted one.
Remove the enzyme completely. Residual activity during later steps trims adapter ends and produces damaged ends that fail to ligate. Heat-inactivate or clean up with beads.
Check the ends of the circle. If the circle was made by ligation, only a fully sealed, nick-free molecule survives; a nicked circle is a linear molecule with a break.
3’ ends can be protected with a phosphorothioate bond, which an exonuclease reads slowly.
Methylation-sensitive digestion
A restriction enzyme that cares about methylation reads the epigenome; one that does not reads the sequence
MspI is insensitive to the CpG methylation at its site, which is why it is used to enrich CpG-rich regions for reduced-representation bisulfite sequencing
Size: a bead ratio or gel keeps fragments in a window, removing adapter dimers and over-long molecules
FACS: one cell at a time on a fluorescent label, which selects cell types before extraction
Fractionation and gradients: select by compartment or by what the RNA is bound to, such as nascent RNA on chromatin or ribosome-bound RNA
Select early, and select on what you can measure
A selection upstream of the library is cheaper than one after it: you do not pay to make a library from molecules you will discard.
Sorting nuclei or cells keeps the cell types you want, but a sort changes the cells: dissociation and fixation introduce stress-response genes and RNA loss.
Fractionation depends on how well the lysis steps separate compartments. Run a marker for each fraction, such as a nuclear RNA that should be absent from the cytoplasmic fraction.
A density gradient or a size column cannot tell two molecules of the same size apart; any selection by a physical property has that limit.
Nojima et al. 2015, doi:10.1016/j.cell.2015.03.027
Trick: suppression PCR
A short adapter at both ends of a fragment lets the strand fold back and anneal to itself faster than a primer can
Only molecules with different ends keep amplifying, so the PCR itself becomes a filter
Siebert et al. 1995, doi:10.1093/nar/23.6.1087
Trick: select by end structure, not by sequence
You do not need to know a sequence to select if the molecule has a feature at its end
A ligation requires a particular end chemistry, PCR requires two different ends, and the flow cell requires both adapters
The library prep itself is a chain of end-structure filters; designing the ends is designing the selection
Trick: carrier nucleic acid for low input
At picogram input, the sample is lost to tube walls, beads and columns, not to the chemistry
A carrier occupies the binding sites; it must not be sequenced
Options: carrier that lacks the ends needed for ligation, DNA from an unrelated species mapped out later, or an RNA that is degraded after extraction
The right choice depends on the protocol; check what the kit supplies
Trick: spike-in standards
A spike-in is a known amount of foreign material added at a defined point, such as at lysis, in proportion to cell number
It is the only way to see a global change, since a normalisation to total reads removes it
Choose a spike-in that cannot map to your genome, and add it before the step you want to control for
Jiang et al. 2011, doi:10.1101/gr.121095.111, Orlando et al. 2014, doi:10.1016/j.celrep.2014.10.018
What each selection costs
Method
Costs you
Fails by
Streptavidin pull-down
low yield on release
non-specific binding to beads
Hybridisation capture
long protocol, duplicates
off-target daisy-chaining, GC bias
RNase H depletion
oligo set per species
incomplete tiling, enzyme left active
Cas9 depletion
guide design
cuts in wanted molecules with the same site
Exonuclease
enzyme removal step
nicked products digested
Restriction selection
enzyme-defined bias
incomplete digestion looks like methylation
Spike-ins
reads spent on spike
spike added at the wrong step
Plan for the failure as well as the method, and run a control that would show it.
Designing a selection: a short worked case
Question: which of 400 genes carry a mutation in 10 ng of cell-free DNA?
Select by sequence: hybridisation capture with baits over the 400 genes. Alternatively, selective circularisation if the targets are small and defined.
Protect the adapters with blockers, and use unique molecular identifiers so duplicates can be told from independent molecules.
Low input: add a carrier that cannot be sequenced, and keep cleanup steps few.
Check: the on-target fraction, and the uniformity of coverage across baits.
Each step uses a block from this deck, and each one has a way to fail that you now know.
Where this connects
Where this block is used
Targeted sequencing — capture, MIPs and reduced representation worked through as whole protocols
mRNA and total RNA — poly(A) selection against rRNA depletion, the commonest selection decision in the course
Chromatin — an antibody selects a protein and brings its DNA along; the tethered-enzyme variants avoid the pull-down
Three-dimensional genome — biotin at the junction is what makes a Hi-C library affordable to sequence
Long reads — Cas9 enrichment, and selection moved onto the instrument as adaptive sampling