Most questions concern a small part of a human genome:
Is a known set of cancer genes mutated in this biopsy?
Is a tumour mutation present at 0.1% in plasma?
Which CpG-rich promoters are methylated in this cell type?
Which of 500 000 variants does this person carry?
Sequencing everything is wasteful; worse, it cannot reach the depth that a rare variant needs. Targeting adds a selection block to the library recipe, and rare-variant work adds a molecule-counting block.
Three ways to select
Amplify the target (PCR), catch it (hybridisation), or copy it out (circularising probes)
A fourth family selects by the genome itself: restriction enzymes, or a guide RNA
The selection block gives the general case; here it is applied to a panel of loci
Each gives up something: uniformity, input, panel size, or flexibility
Amplicons: multiplex PCR with tiled primers
Primer pairs flank each target; many pairs in one tube (multiplex PCR)
For regions longer than one amplicon, tile overlapping amplicons and split them into two pools
The method was made widely known on viral genomes (ARTIC); the logic is the same for tiling a human gene
Quick et al. 2017, doi:10.1038/nprot.2017.066
What goes wrong with amplicons
Every extra primer pair adds more ways for primers to interact
Primers sit on the genome: a common variant under one of them silently removes an allele
Amplicons are the cheapest and fastest option, but they cannot tell a PCR error from a mutation without a UMI
Hybrid capture: make the library, then fish
Biotinylated RNA or DNA baits anneal to fragments from the target; streptavidin beads pull them out
Because the whole library is carried through, capture tolerates a wide variety of fragment ends and targets of any size
Hybridisation takes hours at one temperature, so baits must work together: a Tm question
Gnirke et al. 2009, doi:10.1038/nbt.1523
Worked example: how much enrichment?
Human exome: about 50 Mb of 3.1 Gb, so 1.6% of a random library lands on target.
A capture with 70% on target is a 70 / 1.6, about 44-fold enrichment
At 100x mean target depth you read 100 × 50 Mb / 0.7 = 7.1 Gb, versus 100 × 3.1 Gb = 310 Gb without capture
Reads fall on fragment flanks as well as baits, so depth is highest in the middle of targets and decays at the edges
Real on-target rates depend on the kit and the number of rounds. Treat 70% as an illustration.
Probes that circularise: MIPs and padlocks
The probe’s two arms match the target on each side of a gap; the polymerase fills the gap, the ligase closes the circle
Everything linear is digested: very low background from only the exact target
A random tag in the backbone gives each captured molecule an identity: the smMIP
Hiatt et al. 2013, doi:10.1101/gr.147686.112; Porreca et al. 2007, doi:10.1038/nmeth1110
One padlock, followed to the end
Worth following once in full: the same four steps turn up wherever padlocks are used
The circle is the whole trick. It is the only product that survives the exonuclease, and it carries the captured target inside it
The common use is the left branch: one probe per region, hundreds of regions in one tube, then a single PCR off the shared backbone. The probes do the targeting, so the whole panel amplifies with one primer pair
The same closed circle can instead be copied in place by rolling circle, which is how in-situ methods read it without ever making a library (spatial)
A UMI sitting in the backbone rides through all of it, so what is counted at the end is molecules
Padlocks: Nilsson et al. 1994, doi:10.1126/science.7522346
Cas9-guided enrichment
Block the ends of the whole genome, cut only at the target, and only the cut ends accept adapters
No PCR is needed, so native DNA and its modifications are kept; combine with nanopore for long reads
See nCATS; the need for relatively large input and the modest depth are the trade-offs
Gilpatrick et al. 2020, doi:10.1038/s41587-020-0407-5
Reduced representation: let an enzyme choose
MspI cuts C^CGG (restriction enzymes): sites cluster in CpG-rich DNA such as promoters and CpG islands
Digest, keep short fragments (tens to a couple of hundred bp), and the same positions are sampled in every sample
Same idea, different enzymes: RAD, ddRAD and GBS sample restriction fragments to genotype many individuals
Baird et al. 2008, doi:10.1371/journal.pone.0003376; Elshire et al. 2011, doi:10.1371/journal.pone.0019379
RRBS: reading methylation on the selected fragments
Bisulfite converts unmethylated C to U (read as T); methylated C is protected (the readout)
After MspI digestion, end repair and A-tailing, adapters are ligated, then bisulfite, then PCR
The adapters carry 5-methylcytosine in place of C so that they survive the conversion
Meissner et al. 2008, doi:10.1038/nature07107; see RRBS
RRBS design details worth knowing
The cytosine filled in during end repair is unmethylated by construction, so those end positions cannot be scored
Bisulfite is harsh: the DNA fragments further, so input and complexity matter
The original work used mouse cells; the method applies to human DNA unchanged
Only a fraction of the human genome is covered, mostly CpG-rich regions: a good choice for promoters, a poor one for distal enhancers
A mutation present in 1 of 1000 DNA molecules gives one read in 1000
Errors from PCR, from damage and from the sequencer occur at about the same rate
More depth does not help: you would sample the same errors again
From here the deck works one sample: a tube of plasma from a cancer patient. Each slide settles one decision it forces, and the protocol they add up to is CAPP-Seq.
UMIs: collapse reads to molecules
A random tag put on each molecule before any amplification identifies its descendants
Reads with one tag are one molecule; their consensus removes errors that differ between reads
A variant is believed only if most reads of that molecule agree
Decision 1 for the plasma sample: a tag, or not. Untagged, the floor sits near the error rate; it is the block the tagged form of CAPP-Seq adds
Kinde et al. 2011, doi:10.1073/pnas.1105422108; see Safe-SeqS
Duplex tags: use both strands
A UMI cannot tell a DNA lesion present from the start from a true mutation, since it is copied faithfully
Tag both strands: a true mutation is on both, a lesion on only one
Much stronger error suppression, at the cost of needing both strands of each molecule read
On a few nanograms of plasma DNA that cost is severe: both strands of one molecule must survive the ligation and be sequenced deeply enough to pair
Schmitt et al. 2012, doi:10.1073/pnas.1208715109; see Duplex Sequencing
Where does the tag go?
The tag must be present before the first amplification, otherwise copies cannot be told from originals
Earlier is better, but each protocol only protects against steps downstream of the tag
smMIPs and SureSelect XT HS2 put the tag in the reagent that selects or ligates; Safe-SeqS in the first PCR primer
MBC in the figure is the kit’s name for that tag: a molecular barcode, which is a UMI on the adapter
Decision 2 for the plasma sample: the only step before amplification is the adapter ligation, so that is where the tag has to sit
The plasma sample: molecules, not reads
10 ng of cell-free DNA is about 3000 haploid genomes: a locus is present on 3000 molecules
A variant at 0.1% is on about 3 of them; with that few, chance decides whether any is in your tube
That 0.1% is a variant allele fraction, or VAF: the share of molecules at the locus that carry the variant
Decision 3: sensitivity is set by input molecules, so nothing in the protocol may throw a molecule away, and the limit is blood volume rather than sequencing
Family sizes tell you what to fix
Mostly singletons: sequenced too shallow to correct, or too many molecules for the reads
Large families and few of them: too little input, or too many PCR cycles
A good run balances molecules and reads per molecule: here a mean of 4 gives few singletons
Decision 4: the histogram from the plasma run says which end to move — draw more blood, or buy more reads
SureSelect XT HS2: capture with molecular barcodes
10 to 200 ng of DNA, sheared or enzymatically fragmented, end repair and A-tailing, ligation of adapters
The barcode is in the adapter, so it is present for the index PCR, the capture and the second PCR
Decision 5: tag, amplify, capture, amplify again is the order the four decisions above ask for; this kit is that order as a product. The next slide builds it for plasma instead
Putting it together: CAPP-Seq, followed to the end
The sample writes the protocol: plasma DNA is already short, so nothing is sheared, and the ligation gets a long incubation and excess adapter because a molecule lost there is sensitivity lost
The selector is the design work: baits over regions recurrently mutated in that cancer type, so most patients carry several trackable mutations
Row 7 is the later, tagged version, which is what takes the method to lower VAFs. See CAPP-Seq
Newman et al. 2014, doi:10.1038/nm.3519
Comparing targeting methods
Choose from the question: how many targets, how much DNA, how rare the variant
Smaller panels favour PCR or probes; larger ones favour capture
Read the rows as tendencies: each protocol moves these numbers
Design from the question, then compare
The recurring exercise: question and sample first, then the blocks, then the kit
Ask of every protocol: where does selection happen, where does the tag go, and where does PCR enter?
Summary
Targeting adds a selection block: amplify, catch, circularise, cut or digest
Capture is flexible and scales to big panels; amplicons are fast and cheap; probes need little input
Rare variants are limited by error and by molecule count, not by depth
UMIs correct amplification errors; duplex tags also correct damage; the tag must precede amplification
RRBS uses restriction digestion as selection and bisulfite as the readout
One tube of plasma forced all of that at once, and the protocol it forces is CAPP-Seq
Where this connects
Blocks this protocol uses — make an ordinary library, add a selection, then count molecules
Selection — the four families in general: this deck is one of them applied to a panel
Fragmentation — in RRBS the digest is the fragmentation and the selection at once
End chemistry — blocking every other end is what makes a Cas9 cut the only entry point
Ligases — the circle a padlock must close, and the ends a ligase insists on
Amplification — tiled multiplex PCR, and the errors that cycles add under the variant
Barcodes and UMIs — UMI length, collapsing, duplex tags, and why never in the PCR