Single-cell libraries: combinatorial indexing and multimodal assays
Use cases · NGS library preparation
Start from the question
Atlases of whole organs and embryos need millions of cells. Microfluidic loading is limited by the device and the cost per cell, and doublets rise with throughput.
Remove the hardware: let the cell be its own compartment. Fix the cells so they stay intact, barcode them in a plate, pool, re-split and barcode again. A cell’s barcode is the sequence of wells it passed through.
From compartments, where the arithmetic is worked: three rounds of 96 wells give 884,736 paths, and two cells on one path collide rather than form a doublet, so far fewer cells are loaded than there are paths.
The second half of the deck asks a different question: once every molecule carries a barcode, what other molecules can be given the same barcode? Chromatin, surface proteins, guide RNAs and receptor sequences are all captured by the same trick, with a different handle.
sci-RNA-seq3: RT, ligation and PCR barcodes
![]()
- Nuclei are distributed to wells and reverse-transcribed with an indexed oligo(dT) carrying a UMI; they are pooled and re-split
- An indexed hairpin is ligated to the RT barcode, the nuclei are pooled again and sorted a few tens to a well, and the final index is added by PCR (sci-RNA-seq3)
- The method was built on mouse embryos; the human fetal atlas used the same chemistry
Cao et al. 2019, doi:10.1038/s41586-019-0969-x; Cao et al. 2020, doi:10.1126/science.aba7721
SPLiT-seq: ligating barcodes while the cells stay intact
![]()
- Fixed, permeabilised cells are reverse-transcribed in wells, then barcodes are ligated onto the cDNA’s primer in two further rounds, using short linkers (SPLiT-seq)
- The last oligo also carries the UMI and a biotin; the cells are then lysed and cDNA is purified on streptavidin
- Aliquots of the pool are amplified with a different sublibrary index, one more barcode added per aliquot in that PCR, so the total barcode space multiplies, as does the number of samples
Rosenberg et al. 2018, doi:10.1126/science.aam8999
The cell must keep its molecules
- Fixation or intact nuclei hold the barcoded cDNA inside the cell for the whole procedure
- A leaky cell lets barcoded cDNA escape and re-enter another, which looks like contamination and lowers specificity
- Cells are counted before distribution, because the number per well sets the collision rate
- The cost: no live-cell capture, and RNA captured is lower per cell than in droplets, but each cell costs a fraction as much
The barnyard test
![]()
- Mix human and mouse cells in a known ratio and run the whole protocol on the mixture
- Reads from both genomes in one barcode mark a collision; reads from one genome could still hide one between two cells of that species
- With two species, the real collision rate is about twice the observed mixed rate; split-pool methods are validated this way
sci-ATAC-seq: Tn5 as the first barcoding step
![]()
- Isolated nuclei are tagmented in wells, each with Tn5 loaded with its own index, so accessible DNA is cut and tagged in place (sci-ATAC-seq)
- Nuclei are pooled, sorted into a second plate, and a PCR index is added; three levels (sci-ATAC-seq3) reach hundreds of thousands of cells
- Validated on human cell lines, and later used for the human fetal chromatin atlas
Cusanovich et al. 2015, doi:10.1126/science.aab1601; Domcke et al. 2020, doi:10.1126/science.aba7612
Why chromatin data are sparse
- A diploid cell has two copies of each locus, so an accessible site can be sampled only a handful of times in one cell
- A typical cell gives thousands of unique fragments, spread over hundreds of thousands of potential sites: most entries are zero
- Counts per cell cannot be improved by sequencing deeper once the library is saturated; the limit is the number of molecules in the cell
- This is why analysis aggregates sites (peaks, motifs, bins) and why cell numbers, not depth, carry the statistical power
Multimodal assays: one barcode, two molecules
![]()
- Chromatin and RNA come from the same nucleus: tagment in bulk, then partition nuclei with beads that carry both an RNA-capture oligo and a chromatin-capture oligo
- Both oligos on one bead share the cell barcode, so the two libraries can be tied to the same cell (10x Multiome)
- Two libraries are made from one pre-amplified pool, with their own read structures and sequencing depth
SHARE-seq: the split-pool version
![]()
- Fixed cells are tagmented and reverse-transcribed in the same tube; the Tn5 product and the RT primer share one arm (SHARE-seq)
- Three rounds of hybridisation and ligation add BC1, BC2 and BC3 to both molecule types; biotin on the cDNA primer lets the two libraries be separated by streptavidin
- The ligation chain gives each cell a unique barcode triplet in both assays
Ma et al. 2020, doi:10.1016/j.cell.2020.09.056
CITE-seq: antibodies that look like mRNA
![]()
- Each antibody carries an oligo with a PCR handle, an antibody barcode and a poly(A) tail, so the capture oligo(dT) treats it as an mRNA (CITE-seq)
- The number of antibody barcodes with a given UMI counts the surface proteins on that cell
- The short antibody-derived library is separated from the long cDNA by size, then amplified and indexed on its own
- The same oligo carrying a sample barcode instead of an antibody barcode is cell hashing: pool the samples, overload the device, and a cell with two tags is a doublet (hashing as a block)
Stoeckius et al. 2017, doi:10.1038/nmeth.4380; Peterson et al. 2017, doi:10.1038/nbt.3973
T and B cell receptors: reading the junction
![]()
- Receptor mRNAs are rearranged: the junction that distinguishes the clone (CDR3) is far from either end of the transcript
- A short 3’ tag read does not reach it, and a short 5’ read ends in the variable gene
- The solution is a dedicated library built from the same barcoded cDNA by amplifying out of the constant region
5’ capture and V(D)J enrichment
![]()
- In 5’ kits the barcode is on the template-switch oligo, so it is added at the end of the cDNA that carries the variable region (5’ VDJ kit)
- Nested constant-region primers amplify TCR or BCR cDNA only; full-length receptor sequences are then read in paired-end mode
- Because both chains share one cell barcode, alpha with beta, and heavy with light, are paired, which bulk sequencing cannot do (earlier plate-based work)
Han et al. 2014, doi:10.1038/nbt.2938
Perturb-seq by direct guide capture
![]()
- Every cell carries a guide from a pooled library, and the phenotype read out is that cell’s whole transcriptome — so the guide has to be read in the same cell
- A guide RNA is made by Pol III and is not polyadenylated, so oligo(dT) never sees it. Direct capture puts a capture sequence in the guide scaffold and the matching sequence on the bead oligo, so the guide primes there and is reverse-transcribed in the droplet with the cell’s barcode, like an mRNA (5’ direct capture)
- Nothing is read but the guide itself. The earlier design read a polyadenylated barcode and translated it to a guide through a lookup table, and that barcode is moved onto the wrong guide often enough to matter, by the recombination and template switching between the two RNAs in one virion
Dixit et al. 2016, doi:10.1016/j.cell.2016.11.038; Hill et al. 2018, doi:10.1038/nmeth.4604; Replogle et al. 2020, doi:10.1038/s41587-020-0470-y
CROP-seq: the same guide, routed through an mRNA
![]()
- A variation that needs no capture sequence: the guide cassette sits in the 3’ LTR, and reverse transcription of the viral genome duplicates it into the 5’ LTR, so the provirus has two copies (CROP-seq)
- Pol III makes the working guide from one copy; Pol II makes a polyadenylated mRNA that ends in the other, and oligo(dT) captures it with the transcriptome
- The guide sequence is still what is read, so no lookup table is needed; the reads are rare, and the enrichment PCR that makes them affordable is in reading screens out
Datlinger et al. 2017, doi:10.1038/nmeth.4177
Several guides in one cell
- In a bulk screen two guides in one cell spoil the measurement, which is why the multiplicity of infection is kept low
- When the guides are read per cell that stops being a defect: a cell with two guides measures the pair, so a higher multiplicity turns the screen into a test of how two perturbations combine
- Direct capture was built for this, because each guide carries its own capture sequence and is counted as its own transcript
- The cost is in cells rather than reads: pairs grow as the square of the library, and the cell-number arithmetic of a pooled screen then applies to pairs. A cell whose second guide was not captured looks like a single knockout, so the per-cell assignment rule decides what counts as a double
Replogle et al. 2020, doi:10.1038/s41587-020-0470-y
One barcode, many libraries
![]()
- A single barcoded cDNA pool gives gene expression, receptor, antibody and guide libraries, separated by size or by primer (ECCITE-seq)
- Each library has its own read structure and needs its own share of the sequencing run
- Illustrative budget for 10,000 cells: 20,000 + 5,000 + 5,000 reads per cell = 300 million reads
Mimitou et al. 2019, doi:10.1038/s41592-019-0392-0
Combinatorial or droplets: choosing by constraint
![]()
- Droplets are the easier route for fresh cells, a few thousand to tens of thousands, with high capture and depth
- Split-pool wins when cell numbers are very large, when many samples or conditions must be run together, and when no instrument is available
- Multimodal layers attach to either; the choice is set by what is being measured
The design rule
- The barcode must be attached before the molecules are pooled, to every molecule class you want to track
- It must survive every later step: fixation holds it in the cell, ligation and PCR preserve it, size selection must not discard the short libraries
- The same barcode joins the libraries, so each modality needs its own handle, primer or tag, and its own share of reads
- Check the failure modes: collisions, ambient RNA, PCR chimeras that swap barcodes between molecules, and index hopping between sublibraries
Where this connects
Blocks this protocol uses
- Compartments — split-and-pool as a virtual compartment: a fixed cell is the tube, and the collision rate replaces the doublet rate
- Barcodes and UMIs — how a few hundred oligos make a million addresses, how many of them you may fill, and how a barcode read with errors is corrected
- Attaching a handle — each round adds a handle by RT, ligation or PCR; the same five ways, applied three times to one molecule
- Ligases, kinases, phosphatases — rounds 2 and 3 of SPLiT-seq and SHARE-seq are splinted ligations, which is why the linker oligo matters as much as the barcode
- Transposases and modifying enzymes — an indexed Tn5 makes tagmentation itself the first barcoding step in sci-ATAC-seq
- Selection — biotin on the cDNA primer is how one barcoded pool is split into two libraries on streptavidin
Before this
- Pooled screens — the vector, the LTR duplication, the Pol II and Pol III promoters and the virion trap, all taught before the guide is read in single cells
- Reading screens out — the enrichment PCR that makes rare guide reads affordable
Where these blocks are also used
- Chromatin — ATAC and CUT&Tag in bulk; sci-ATAC is that assay with an indexed enzyme