Single-cell libraries: plates, droplets and microwells
Use cases · NGS library preparation
Start from the question
A tissue is a mixture of cell types and states, and a bulk library averages them. To ask which cells express what, you need one library per cell, or something equivalent.
A human cell holds on the order of 10^5 mRNA molecules, in a few picograms of RNA. That is a tiny sample, and the protocol must capture a useful share of it without losing track of which cell it came from.
The organising idea of this unit: the blocks are the ones you already know (RT, template switching, amplification, tagmentation, adapters). What is new is that every molecule must carry a compartment barcode from the moment it is made, so that the cells can be pooled and still be told apart.
The barcode is what makes pooling possible
![]()
- Cost and batch effects scale with the number of libraries, so pool as early as the chemistry allows
- A barcode on the first-strand primer tags every cDNA of a cell at the moment it is made
- Everything after pooling is an ordinary library molecule; everything before it is where single-cell methods differ
Four ways to give each cell its own compartment
![]()
- Plates and microwells: a physical well holds one cell; the barcode comes in the primer of that well, or on a bead in it
- Droplets: a microfluidic device puts one cell and one barcoded bead in each droplet of oil
- The cell itself: fixed cells are barcoded by successive split and pool rounds, so no hardware isolates them (next deck)
SMART-seq: one cell per well, full-length cDNA
![]()
- Reverse transcriptase adds a few non-templated Cs at the 5’ end of a cDNA that reaches the cap; a template-switch oligo pairs there and the enzyme copies it: full-length cDNA with a known handle at each end (SMART-seq2)
- One PCR primer amplifies every cDNA; Tn5 then tagments, and the well index is added by index PCR (the TSO itself is designed in the low-input RNA deck)
- The cell is never barcoded inside the molecule, so cells cannot be pooled before the end
Picelli et al. 2013, doi:10.1038/nmeth.2639
Tag or full length: a design choice
- 3’ or 5’ tag methods read one end of each mRNA, which is enough to count molecules and identify cell types, and allow UMIs
- Full-length methods read the whole transcript: isoforms, splice junctions and variants within a cell, at higher cost per cell
- SMART-seq3 puts a UMI at the 5’ end and combines the two: reads from the UMI-carrying end count molecules, and internal reads give isoform and variant information
- The question decides: which cells exist wants thousands of cells and a tag; what does this cell express in detail wants a plate and a full-length protocol
Hagemann-Jensen et al. 2020, doi:10.1038/s41587-020-0497-0
CEL-seq and MARS-seq: barcode the RT primer, then pool
![]()
- The reverse-transcription primer carries a cell barcode, a UMI and oligo(dT); after RT the wells are pooled, and one tube goes through the rest (CEL-seq, MARS-seq)
- T7 in vitro transcription amplifies linearly, which avoids the exponential bias of early PCR cycles
- The cells are still sorted into wells, so the experimenter knows which cell is where (for example by index sorting)
- The UMI rides on that first-strand primer because a tag added later would count copies, not molecules (barcodes and UMIs)
Hashimshony et al. 2012, doi:10.1016/j.celrep.2012.08.003; Jaitin et al. 2014, doi:10.1126/science.1247651
10x 3’ v3: one cell, one gel bead, one GEM
![]()
- A chip brings a stream of cells together with a stream of gel beads and cuts the flow into droplets of oil of about a nanolitre, called GEMs (3’ v3 protocol)
- Every oligo on one bead carries the same 16 nt cell barcode, its own 12 nt UMI, and poly(dT)VN to prime on poly(A)
- Cells arrive at random, so most GEMs are empty and a few hold two cells; the loading rate chosen sets that doublet fraction (worked in compartments)
Inside the GEM: reverse transcription, then a handle at the other end
- The gel bead dissolves and releases its oligos; the mRNA primes on poly(dT)VN and is copied, so the barcode and UMI are on the cDNA while the droplet still exists
- Reaching the cap, the reverse transcriptase adds a few non-templated Cs and switches to a template-switch oligo, which leaves a second known handle at the 5’ end
- The cDNA now has one handle at each end, so a single primer pair amplifies every molecule in the pool whatever gene it came from
Break the emulsion: from here it is an ordinary library
![]()
- The barcode must be on the cDNA before the oil is broken; afterwards a pool of millions of molecules cannot be traced back to cells
- The pooled cDNA is amplified off its two handles, then fragmented, end-repaired and A-tailed (end chemistry), and the Read 2 adapter is ligated
- Index PCR adds the sample index and the P5 and P7 ends; since the cDNA was fragmented, only the 3’-most fragment carries both the cell barcode and the Read 2 adapter
The read structure that falls out of it
![]()
- The bead oligo sets the layout: Read 1 holds the 16 nt cell barcode and the 12 nt UMI, Read 2 holds the cDNA, and the index read holds the sample index
- The run is set up to match: about 28 cycles for Read 1, about 90 for Read 2, in the read-structure notation of the sequencer deck
- Reading only the 3’ end keeps the library short and puts the UMI next to the barcode, so one short read identifies the cell and the molecule at once
Which barcodes of this library are cells?
![]()
- Most of the barcodes seen are GEMs that held no cell but still captured RNA leaked from broken ones: ambient RNA
- Ranking the barcodes by UMI count gives a plateau of cells and a tail; the knee is the first cut, refined by statistical models (where the knee is derived)
- Ambient RNA also contaminates real cells; correct it before calling a gene expressed in a cell type Young and Behjati 2020, doi:10.1093/gigascience/giaa151
- A barcode one mismatch from exactly one entry of the bead whitelist is corrected to it; two equally close entries, and the read is dropped (why that is safe)
The same trace, a different bead
![]()
- Drop-seq: rigid beads load at random, so most droplets have none, and RT waits until the pooled beads are out of the oil
- inDrop: hydrogel beads close-pack, so nearly every droplet gets one; HyDrop beads are made in the lab, for RNA or ATAC
- Microwells (Seq-Well, BD Rhapsody): gravity instead of a chip, and a membrane instead of oil
- The bead sets loading efficiency and when the barcode is released; after that, the trace above
Macosko et al. 2015, doi:10.1016/j.cell.2015.05.002; Klein et al. 2015, doi:10.1016/j.cell.2015.04.044; De Rop et al. 2022, doi:10.7554/eLife.73971; Gierahn et al. 2017, doi:10.1038/nmeth.4179
Fresh cells, nuclei and fixed cells
- Whole cells need fast, gentle dissociation; some tissue types (neurons, adipocytes, frozen biopsies) do not survive it
- Nuclei can be isolated from frozen tissue; they carry less cytoplasmic RNA and more intronic reads, so a gene-expression reference with introns is used
- Fixed cells decouple sampling from processing: hybridised probes can replace RT as the capture step (Flex), and combinatorial methods need fixation by design
- Each choice changes the capture chemistry, but the barcode logic is the same
Plates and droplets answer different questions
![]()
- Plates give depth and full length for a limited number of cells you chose
- Droplets and microwells give thousands of cells with no selection, at modest depth per cell
- A systematic comparison of protocols is the best way to see the trade-off Ziegenhain et al. 2017, doi:10.1016/j.molcel.2017.01.023
The read budget
- 5,000 cells with 3’ droplet libraries at 50,000 reads per cell: 250 million reads
- 384 cells with SMART-seq at 1 million reads per cell: 384 million reads for a much smaller experiment
- The first reads of each library are the most informative, and a library saturates: past a point, extra reads re-sequence molecules already counted
- Check how many new UMIs the last 10% of reads added before ordering a deeper run
One question to ask of any single-cell protocol
- Where does the barcode enter, and what physical compartment does it label? A well, a droplet, a bead in a microwell
- When are the cells pooled? After RT (CEL-seq, MARS-seq, droplets) or only at the end (SMART-seq)
- What does the 3’ tag give up? Isoforms, splice junctions and variants, for the sake of scale
- The next deck removes the hardware: cells that are their own compartments, and assays that measure more than RNA
Where this connects
Blocks this protocol uses
- Compartments — the well, the droplet and the microwell, with the Poisson arithmetic that sets doublets, empty droplets and the knee in the barcode-rank plot
- Barcodes and UMIs — why a whitelist can be corrected at one mismatch, why the UMI must go on the RT primer, and how the read budget is divided
- Attaching a handle — the two handles every protocol here uses: the barcoded RT primer, and the template-switch oligo at the other end
- Polymerases and RTs — template switching is an RT side-activity, and which enzyme you buy decides how well it works
- Amplification — IVT in CEL-seq is linear precisely to avoid the exponential bias of early PCR cycles; duplicates are what the UMI exists to collapse
- Fragmentation — tagmenting the amplified cDNA is why only the 3’ end carries both the barcode and the second adapter
Before this
- mRNA and total RNA — poly(A) capture, RT priming and second strand; the single-cell version is the same chemistry in a nanolitre
Where this goes next