Quiz: FLIM-FRET and metabolic imaging
Before this unit: Frequency domain and phasors (previous unit); Day 49: FRET; Day 3: Bit depth and noise.
See also: Day 5: Deconvolution; Day 47: Spectral unmixing.
Short questions to test your understanding. Try each on paper first, then open the answer. 80 MHz: ω = 0.503 rad/ns.
Q1. Why does FRET shorten the donor’s lifetime?
The lifetime is one over the total rate of leaving the excited state.
Transfer to the acceptor is an extra way to leave the excited state. More exits, higher total rate, shorter mean waiting time: 1/\tau_{DA} = 1/\tau_D + k_T.
Q2. The donor alone has τ = 2.5 ns; with the acceptor 1.5 ns. What is E, and which distance does it suggest for R_0 = 5 nm?
E = 1 - \tau_{DA}/\tau_D; r = R_0(1/E - 1)^{1/6}.
E = 1 − 1.5/2.5 = 0.4. r = 5 \cdot 1.5^{1/6} = 5.35 nm.
Q3. Why does lifetime-based FRET not need the bleed-through and cross-excitation corrections of intensity-based FRET?
Which molecule’s light is measured?
Only the donor’s decay is recorded, and its lifetime does not depend on how many donors or acceptors there are. Intensity FRET compares channels whose values depend on concentrations, bleed-through and cross-excitation, which must be measured and subtracted.
Q4. 30 % of the donors interact, at E = 0.6 (\tau_D = 2.5 ns). Where on the line from the donor point to the FRET point does the pixel’s phasor lie?
Position = photon fraction; photons per molecule ∝ lifetime.
\tau_{DA} = 1.0 ns. Photon fraction f = 0.3 \cdot 1.0/(0.3 \cdot 1.0 + 0.7 \cdot 2.5) = 0.15: only 15 % of the way from the donor point, although 30 % of the molecules interact.
Q5. Two experiments give the same mean donor lifetime. Could the interaction still be different? How would you tell?
Efficiency and fraction.
Yes: all donors at a low efficiency, or fewer donors at a high efficiency, can give the same mean lifetime (with τ_D = 2.5 ns: all at E = 0.3, or 71 % at E = 0.6, both 1.75 ns). A bi-exponential fit with \tau_D fixed, or the phasor plot, separates them: the first lies on the semicircle, the second inside it, on the line from the donor point.
Q6. Free NADH (0.4 ns) and bound NADH (2.5 ns): a cell’s phasor lies 40 % of the way from free to bound. Is 40 % of its NADH bound?
Photon fraction vs molecule fraction.
No, 40 % of the photons come from bound NADH. Per molecule, bound NADH gives about 2.5/0.4 = 6 times more photons (assuming the same radiative rate), so the molecule fraction is (0.4/2.5)/(0.4/2.5 + 0.6/0.4) = 0.10.
Q7. A FRET pixel’s phasor lies outside the semicircle. What could cause that?
Which kind of decay has a phasor outside the semicircle?
A component that rises before it decays: acceptor emission leaking into the donor channel (it is excited through FRET, so it lags behind). Its phasor is the product P_{DA}P_A, outside the semicircle. Noise or a wrong calibration can also push points just outside.
Q8. (math) Show that the amplitude-weighted mean lifetime of a population with interacting fraction α and efficiency E is \tau_D(1 - \alpha E).
\bar\tau_a = (1 - \alpha)\tau_D + \alpha\tau_{DA}.
\bar\tau_a = (1 - \alpha)\tau_D + \alpha\tau_D(1 - E) = \tau_D(1 - \alpha E). So 1 - \bar\tau_a/\tau_D = \alpha E: the “apparent efficiency” from the amplitude-weighted mean is the product of fraction and efficiency, and cannot separate them.