Quiz: frequency domain and phasors

Short questions to test your understanding. Try each on paper first, then open the answer. 80 MHz: ω = 2π · 0.08 GHz = 0.503 rad/ns.


Q1. Light modulated as a wave excites a sample. Why is the emission a wave of the same frequency, and what are the two things that change?

Emission = excitation ∗ decay. What does a convolution do to a wave?

Waves are eigenvectors of convolution: convolving a wave with the decay gives the same wave times one complex number (the decay’s Fourier coefficient at that frequency). Its angle is the phase delay φ (the emission lags) and its length is the modulation m < 1 (the emission is flattened).


Q2. A pixel’s phasor is (0.8, 0.4) at 80 MHz. Is it a single exponential? Which lifetime?

Check (g - \tfrac12)^2 + s^2 = \tfrac14; then \tau = s/(g\omega).

0.3^2 + 0.4^2 = 0.25: on the semicircle, so consistent with one exponential. \tau = 0.4/(0.8 \cdot 0.503) = 0.99 ns.


Q3. Why does a pixel containing two species lie on the straight line between their phasors? Where on that line?

The phasor is a weighted average of e^{i\omega t} over the photons.

The phasor is linear in the decay and divided by the total intensity, so it is the photon-weighted average of the two species’ phasors: a point on the chord between them. Its position is the photon fraction (lever rule): with 30 % of the photons from species B, it lies 30 % of the way from A to B.


Q4. Equal numbers of molecules of a 0.4 ns and a 4 ns dye share a pixel. Is the pixel’s phasor near the middle of the chord?

Photons per molecule are proportional to the lifetime.

No. The 4 ns dye gives 10 times more photons per molecule: photon fractions 0.09 and 0.91. The point lies 91 % of the way towards the 4 ns end. Converting back to molecules needs the lifetimes (and the assumption of equal brightness per unit lifetime).


Q5. Without calibration, all phasors of an image appear rotated anticlockwise and slightly shrunk. What causes this, and how is it fixed?

What does the convolution theorem say about the IRF?

The measured decay is the true decay convolved with the IRF, so the measured phasor is the true one multiplied by the IRF’s phasor: its delay rotates, its width shrinks. Measure a reference of known lifetime with the same settings and divide out the complex factor (one division for the whole image).


Q6. Calibration divides by the IRF’s phasor, i.e. deconvolves. Why does it not blow up the noise like the inverse filter of the image formation and deconvolution days?

How large is the IRF’s response at the laser’s repetition frequency?

It divides at one low frequency only (80 MHz for an IRF a few hundred picoseconds wide), where the IRF’s response is close to 1 (e.g. ×0.96 and a rotation). The inverse filter divides at every frequency, including high ones where the response is near 0.


Q7. In a dim image, the phasor cloud of a pure dye is spread out, and some of it is pulled towards (0, 0). Explain both effects.

What is the phasor of a flat background?

Few photons per pixel: the average of e^{i\omega t} over N photons scatters with a spread of about \tfrac12/\sqrt N per coordinate. A flat background averages e^{i\omega t} over a whole period: zero. Pixels with background are mixtures of the dye and “background at (0, 0)”, so they lie on the line towards the origin, further for dimmer pixels.


Q8. (math) Show that the phasor of e^{-t/\tau} satisfies (g - \tfrac12)^2 + s^2 = \tfrac14.

P = 1/(1 - i\omega\tau). Compute g^2 + s^2 and compare with g.

g = 1/(1 + \omega^2\tau^2), s = \omega\tau/(1 + \omega^2\tau^2), so g^2 + s^2 = (1 + \omega^2\tau^2)/(1 + \omega^2\tau^2)^2 = g. Then g^2 - g + s^2 = 0, i.e. (g - \tfrac12)^2 + s^2 = \tfrac14.