Exercises — The enzyme toolbox

Pen and paper. Try each one before opening the Hint, and the hint before the Solution: the reasoning is the point, not the answer.

Have the NEB selection charts open for every question. They list polymerase, ligase, nuclease and modifying-enzyme properties in the same columns the lectures use. (The site blocks automated tools, so use a browser.) Where an answer depends on the exact product, say so and name the column you would check.

Part 1 — Pick the enzyme and name the deciding column

E1. Fill in without displacing

A fragment has a 5’ overhang of four bases on each end and the other strand is a continuous backbone. You want to fill in the overhang so the end is blunt, and you must not displace or degrade anything. Which polymerase type, and which column decides?

Three enzymes could fill in. Two of them also do something to a strand that is in the way. The strand in front of the filling polymerase here is the end of the duplex itself.

T4 DNA polymerase. The deciding column is strand displacement: T4 DNA polymerase has none, so it fills in and stops at the blunt end. Klenow also fills in, but it displaces, which would cause trouble if the end were part of a nick. Taq degrades the downstream strand through its 5’→3’ exo, and also adds an A.

The 3’→5’ exonuclease column is a bonus rather than the decider: it lets the same enzyme trim a 3’ overhang if there is one.

E2. Amplify a bisulfite-converted template

After bisulfite treatment, every unmethylated cytosine in the template has become uracil. You want to PCR a short region. Which polymerase family can you use, and which column decides? Name one that will fail silently.

What does the template contain that it did not contain before the treatment? Which family detects that base?

The deciding column is dU tolerance. A Taq-type enzyme reads through uracil and works. A high-fidelity archaeal family-B polymerase (Pfu-like, which includes the common HiFi enzymes) has a read-ahead pocket that stalls at uracil, and gives little or no product. A uracil-tolerant variant of the HiFi enzyme works and keeps the fidelity.

It fails “silently” in the sense that nothing is wrong with the reaction: the primers, the buffer and the cycling are fine, and the template is not copied. If the bisulfite control also fails, suspect the enzyme before the DNA.

E3. Copy an RNA:DNA hybrid

You have first-strand cDNA still paired with its RNA. List what the second-strand polymerase must be able to do, and name the enzyme combination that does it.

Something has to make primers. Something has to start at them. Something has to remove the RNA in front of the new strand.

  1. RNase H nicks the RNA, leaving short RNA pieces with 3’-OH ends: these are the primers
  2. RNA primer extension: the polymerase must start from an RNA 3’-OH. Pol I does
  3. Nick extension and 5’→3’ exo: the polymerase must remove the RNA in front of it and keep going, which is nick translation

So the answer is Pol I with RNase H (the Gubler–Hoffman method). A HiFi enzyme fails the RNA-primer column, and T4 DNA polymerase fails the nick extension one.

Part 2 — Read the row

E4. What can this row do?

A chart row reads: 3’→5’ exo: no · 5’→3’ exo: no · strand displacement: strong · RT activity: weak · 3’ end: +A, partly · temperature: 60–65 °C · dU: tolerant. For each of these steps say can or cannot, and why: a. end repair of sheared DNA b. LAMP-style amplification at constant temperature c. a proofreading library PCR d. one-base A-tailing e. copying a rolling-circle template

The row is a Bst-type large fragment. Think about which of its columns each step needs.

  1. Cannot. It displaces strands (strong) and leaves a mixed +A end, so the product is neither blunt nor uniform; and there is no 3’→5’ exo to trim a 3’ overhang.
  2. Can. Strong displacement and 60–65 °C is the profile of isothermal amplification.
  3. Cannot. No 3’→5’ exo means no proofreading: the error rate is moderate.
  4. Partly. It adds A, but incompletely. A dedicated A-tailing enzyme is more reliable.
  5. Can. Strong displacement lets it roll round a circle, though phi29 is better.

E5. And this one?

A second row reads: 3’→5’ exo: strong · 5’→3’ exo: no · strand displacement: none · 3’ end: blunt · temperature: 12–37 °C · dU: tolerant · RT: no. What is the enzyme type, and which of the steps in E4 can it do?

It is a T4 DNA polymerase. It can do (a) end repair, because it fills in and trims and leaves a blunt end without displacing anything. It cannot do (b), (c), (d) or (e): it is not thermostable, has no displacement, and leaves a blunt end rather than +A. It could be used for gap filling that must not disturb the neighbouring strand.

E6. When does fidelity matter?

Library PCR runs 10 doublings on a 300 bp insert. Estimate the mean number of polymerase errors per molecule for a Taq-class enzyme at 1e-4 per base per doubling, and for a high-fidelity enzyme at 1e-6. Sequencing error is about 1e-3 per base. Which one dominates the differences you see in the reads, and for which application would you still choose the high-fidelity enzyme?

Mean errors ≈ length × rate × doublings.

Taq-class: 300 × 1e-4 × 10 = 0.3 errors per molecule. High-fidelity: 300 × 1e-6 × 10 = 0.003. Sequencing: 300 × 1e-3 = 0.3 errors per read.

For counting reads, the three numbers say that the sequencer already contributes as many errors as the Taq-class PCR, so fidelity is not the bottleneck. You would still choose the high-fidelity enzyme for low-frequency variants, for long amplicons (more bases, more doublings) and for cloning, where the error you introduce becomes a sequence you keep. These are illustrative orders of magnitude and the real rates depend on the assay.

Part 3 — Traps and silent failures

E7. The blocker that started priming

A PCR uses a 3’-C3-spacer “blocker” oligo to suppress amplification of a wild-type allele. With a standard Taq polymerase it works. After switching to a proofreading polymerase for better fidelity, the wild-type allele amplifies as well as the mutant. Why? Give two fixes.

What does a proofreading enzyme do to an unpaired or unusual 3’ end?

The 3’→5’ exonuclease removes the spacer and the last bases of the blocker, exposing a 3’-OH that the polymerase then extends. The block was chemical, and the enzyme has an activity that undoes chemistry at the 3’ end.

Fixes: (1) use a polymerase without 3’→5’ exo for that reaction; (2) protect the 3’ end of the blocker with phosphorothioate bonds so the exonuclease cannot chew in. A third option is a blocker whose 3’ end has mismatches to the template, so it cannot be extended even after trimming.

E8. The strand information that vanished

A stranded RNA-seq library uses dUTP in the second strand and a polymerase that cannot read uracil. After a supplier change the library still works, but about half of the reads align to the wrong strand. The library QC is normal. What changed, and why did nothing warn you?

The new polymerase is uracil-tolerant. The dU strand is no longer excluded, so both strands amplify and the library is unstranded. Nothing warns you because both strands give perfectly good reads; the library concentration, size and yield all look right.

The defence is a strandedness check on a spike-in or a known gene in every batch, and a rule that any change to the polymerase in a dUTP-marked protocol is a change to a critical property (the dU tolerance column).

E9. Which adapter strand needs the phosphate?

You order the two strands of a double-stranded adapter with a single 3’ T overhang. Strand X (the one carrying the 3’ T) is ordered with a 5’-phosphate; strand Y (the other) is ordered without. The inserts are end-repaired and A-tailed, so they carry 5’-phosphates. Predict what happens at the junction on each strand. Then predict it again if the inserts have been dephosphorylated.

Draw the junction. Which adapter 5’ end meets the insert’s 3’-A, and which adapter 3’ end meets the insert’s 5’ end? A ligase needs a 5’-P on whichever strand supplies the 5’ side.

The adapter’s 3’-T (strand X) meets the insert’s 5’ end: the phosphate comes from the insert, so this strand joins. Strand X’s own 5’-phosphate is at the far end of the adapter and is not used. Strand Y’s 5’ end meets the insert’s 3’-A: here the adapter must supply the phosphate and does not, so this strand is not joined and a nick remains. The molecule is a usable library template, and PCR melts the nick open.

If the inserts are dephosphorylated as well, neither junction has a 5’-phosphate. Nothing joins covalently, the single A:T pairs fall apart, and you get almost no product with no error message. The strand that needs the phosphate is the one that supplies the 5’ side of the junction, not the one with the overhang.

E10. The two enzymes that cancel

A protocol dephosphorylates fragments with a phosphatase, adds adapters with a 5’-phosphate, then ligates. Yield is zero. The phosphatase’s inactivation step is a 10-minute incubation at 37 °C “to save time”. Explain the failure and a better design.

A heat-labile phosphatase needs about 65 °C to be killed. At 37 °C it is still active when the adapters are added, and it removes the 5’-phosphate from the adapters as well as the fragments. No end can then act as a donor.

Better: inactivate at the temperature the datasheet gives, or clean up on beads between the two steps. A pilot that skips the phosphatase would have shown the problem at once.

E11. Pick the ligase

For each situation name a ligase type and the chart column that decides. a. Attach a 3’ adapter to a 22-nt RNA without circularising the RNA b. Close a single-stranded DNA into a circle c. Join an RNA to a DNA oligo, using a bridging DNA oligo d. Join two blunt dsDNA ends at low concentration

For each, ask: what is the donor, and is it single or double stranded?

  1. Truncated T4 RNA ligase 2 with a pre-adenylated, 3’-blocked adapter. Deciding column: donor: pre-adenylated, no ATP, so nothing else can join.
  2. A single-strand circularising ligase (CircLigase-type, or T4 RNA ligase 1). Deciding column: substrate is single-stranded.
  3. A ligase for RNA:DNA hybrids (the Chlorella virus type) on a DNA splint. Deciding column: substrate: a nick in a hybrid.
  4. T4 DNA ligase with PEG. Blunt ends are the slowest substrate, so crowding agents and enzyme concentration decide. E. coli DNA ligase would not do it.

E12. The tagmentation library that would not amplify

You tagment 50 ng of human DNA with a loaded Tn5 and go straight to PCR. The DNA is clearly fragmented on a gel, yet PCR gives almost no product. Name two causes tied to the mechanism of tagmentation.

Two things are true of the product of the transposase immediately after the reaction. One concerns the enzyme, the other the structure of the ends.

  1. Tn5 remains bound to the product. It must be stripped (SDS, heat or a column) before PCR; otherwise the polymerase meets a protein-covered template.
  2. There is a 9 nt gap between each fragment’s 3’-OH and the adapter beyond it. A polymerase must fill it before the primer site exists as a duplex; a protocol that skips the initial 72 °C extension gives much less product.

Check also whether the loaded Tn5 was in excess (fragments too short) and whether the adapters were loaded as two different types, since half the fragments are unproductive by design.

Self-check

Answer without looking anything up.

  1. Which polymerase property decides whether an A-tail survives?
  2. Name the three things a polymerase does when it meets a strand in front of it.
  3. Which column explains why a stranded-RNA-seq library loses strand information?
  4. What are the two requirements for ligation to happen at a nick?
  5. Why is a rSAP step heat-inactivated?
  6. What does a Type IIS enzyme offer that a Type II enzyme does not?
  7. What does Tn5 leave behind in the target after cutting?
  1. The 3’→5’ exonuclease. If present, the A is removed; if absent, it stays.
  2. It stops, displaces the strand, or degrades it (5’→3’ exo).
  3. dU tolerance: a polymerase that reads through uracil keeps the marked strand.
  4. A 5’-phosphate on one side and a 3’-OH on the other, in a duplex.
  5. So it does not remove the phosphate from the adapters added next.
  6. It cuts outside its recognition site, so the overhang can be designed.
  7. A 9 nt gap beside each adapter, which a polymerase must fill.

Going further

  • Open a kit manual that you use. For every enzyme named, write down its end-state in and out, and find the chart column that would break the step if it were wrong.
  • Take the walk-through slide of the transposase deck and replace each enzyme by a wrong one: note which row breaks first and how you would notice.